Provectus Environmental Products
Back to Projects

Case Study — ISCO and Enhanced Bioremediation

Former Gas Station

Raleigh, North Carolina

Project Summary

The site is a former gas station located in Raleigh, North Carolina. The site was contaminated with benzene, toluene, ethylbenzene, xylene (BTEX), chlorobenzene, naphthalene, dichlorobenzenes, and isopropylbenzene. The area of concern was approximately 2,100 sq ft with a target vertical interval from 12 to 30 feet below ground surface (ft bgs).

The geology at the site is primarily sandy silt with depth to groundwater at approximately 16 ft bgs. Two areas of concern were targeted utilizing Provect-OX® (US Patent 9,126,245), which is an advanced chemical oxidation and accelerated bioremediation technology.

Remedial Plan

Innovative Environmental Technologies, Inc. (IET) developed the remedial design and applied Provect-OX® to the subsurface via a patented injection process and apparatus (US Patent 7,044,152) such that the activation processes occur in a controlled manner. A total of 11 injection points and 3,600 lbs of Provect-OX® were utilized to treat the two areas of concern.

The Provect-OX® rapidly oxidizes the organic contaminants present in soil and groundwater and provides long-term, sustained secondary bioremediation to manage residuals and prevent contaminant rebound. This is accomplished by using ferric iron (Fe III) as a safe and effective means of activating persulfate, which rapidly yields sulfate and ferrate radicals for chemical oxidation treatment. The process also enhances subsequent utilization of sulfate and iron as terminal electron acceptors for facultative redox reactions to support secondary biodegradation of any residual contaminant mass.

Results

  • MW-1 exhibits non-detect concentrations for all contaminants of interest (COI) other than xylenes (99% decrease) and 1,4-dichlorobenzene (68% decrease).
  • All COIs in MW-4 were non-detect following the Provect-OX® injection program.
  • Additional contaminant concentration decreases in MW-1 are expected due to the iron and sulfate enhanced bioremediation processes.

Table 1. VOC Data for MW-1 and MW-4 (µg/L)

ContaminantMW-1MW-4
Sampling Date09/12/201210/02/201309/12/201210/02/2013
Benzene0.3JND13ND
Toluene0.8JND2.89ND
Ethylbenzene2.5NDNDND
Total Xylenes820.916ND
Naphthalene6.6ND8.4ND
Chlorobenzene1.0ND13ND
1,2-Dichlorobenzene18ND18ND
1,3-Dichlorobenzene2.7ND0.8JND
1,4-Dichlorobenzene9.93.23.6ND
Isopropylbenzene12ND4.2JND

Project Details

Location
Raleigh, NC
Technology
ISCO and Enhanced Bioremediation
Product Used
Provect-OX®
Contaminants
BTEX, Chlorobenzene, Naphthalene
Treatment Area
2,100 sq ft; 12 to 30 ft bgs
Application
3,600 lbs of Provect-OX®
11 Injection Points
Contractor
Innovative Environmental Technologies, Inc.

Interested in Provect-OX®?

Learn how ISCO and enhanced bioremediation can address petroleum hydrocarbon contamination at your site.

Request a Quote